1. SUB DISTRIBUTION PANEL
The sub distribution panel or board consists of a basic frame with all the necessary electrical components such as main isolating switches, emergency shut-down mechanism, RCDs, line circuit breakers, controls and contactors for individual workgroups. The distributor can supply multiple workgroups with electrical power independently. We design & manufacture the Sub Distribution Panel according to the Customers’ need through reliability, selectivity, durability & time of taking action to Product Quality which comply with cost effective, long life and application-wise.
Applications | Operation, Control & protection of distribution network |
System | 3 Phase, 3 or 4 wire, 50Hz |
Rated Current | Upto 3200 Amps |
Operational Voltage | 110/230v 415v AC |
Rated Insulation | 1000v |
Rated Service Voltage | 690v |
Ambient Temperature | 45 Deg C |
Short Time Current | 50KA for 1Sec, 105KA peak |
Degree of Protection | IP42-IP54 |
Form of Sepration | Upto 3B/4B (Optional Type 5) |
Type Tested for | Short Time Current withstand Temperature Rise Degree of Protection |
Bus Bar System | Interleaved above 1600A |
Bus Bar | Aluminium or Copper |
Ref. Standard | IEC61439-12009, IS:8623 |
Feeder Configuration | Semi Drowout or Fix Type |
2. LIGHTING DISTRIBUTION PANEL
Lighting Distribution Boards are an integral and essential part of every building project and it must be designed, manufactured and installed all in accordance with the safety standards. In most of the cases it operates a layman wherein others operate dedicated or trained personnel’s. This new generation of panel board products represents the high level of engineering innovation expected from SCPPL.
Applications | Operation, Control & protection of distribution network |
System | 3 Phase, 3 or 4 wire, 50Hz |
Rated Current | Upto 2000 Amps |
Operational Voltage | 110/230v 415v AC |
Rated Insulation | 1000v |
Rated Service Voltage | 690v |
Ambient Temperature | 45 Deg C |
Short Time Current | 50KA for 1Sec, 105KA peak |
Degree of Protection | IP42-IP54 |
Form of Sepration | Upto 3B/4B (Optional Type 5) |
Type Tested for | Short Time Current withstand Temperature Rise Degree of Protection |
Bus Bar System | Interleaved above 1600A |
Bus Bar | Aluminium or Copper |
Ref. Standard | IEC61439-12009, IS:8623 |
Feeder Configuration | Semi Drowout or Fix Type |
3. MAIN DISTRIBUTION PANEL
An MDB is a panel or enclosure that houses the fuses, circuit breakers and ground leakage protection units where the electrical energy, which is used to distribute electrical power to numerous individual circuits or consumer points, is taken in from the transformer or an upstream panel. An MDB typically has a single or multiple incoming power sources and includes main circuit breakers and residual current or earth leakage protection devices.
Applications | Operation, Control & protection of distribution network |
System | 3 Phase, 3 or 4 wire, 50Hz |
Rated Current | Upto 4000 Amps |
Operational Voltage | 110/230v 415v AC |
Rated Insulation | 1000v |
Rated Service Voltage | 690v |
Ambient Temperature | 45 Deg C |
Short Time Current | 50KA for 1Sec, 105KA peak |
Degree of Protection | IP42-IP54 |
Form of Sepration | Upto 3B/4B (Optional Type 5) |
Type Tested for | Short Time Current withstand Temperature Rise Degree of Protection |
Bus Bar System | Interleaved above 1600A |
Bus Bar | Aluminium or Copper |
Ref. Standard | IEC61439-12009, IS:8623 |
Feeder Configuration | Semi Drowout or Fix Type |